AIR

(Max) nominal output power (kW) 10.10
Minimum output power (kW) 2.90
Efficiency at Max (%) 90.30
Hopper capacity (lt) 42.00
Pellet hourly consumption (Min) (kg/h) 0.70
Pellet hourly consumption (Max) (kg/h) 2.20
Efficiency at minimum (h) 39.0
Autonomy (Max) (h) 13.00
Heatable volume (m³) * 248
Smoke outlet (cm) 8
Net weight (kg) 138
Temperature of exhaust smoke at Max (ºC) 180
Mass of smoke (g/s) 8.00

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m³

COMFORT AIR 12

(Max) nominal output power (kW) 12.10
Minimum output power (kW) 3.30
Efficiency at Max (%) 90.50
Hopper capacity (lt) 42.00
Pellet hourly consumption (Min) (kg/h) 0.80
Pellet hourly consumption (Max) (kg/h) 2.70
Efficiency at minimum (h) 34.0
Autonomy (Max) (h) 10.00
Heatable volume (m³) * 297
Smoke outlet (cm) 8
Net weight (kg) 142
Temperature of exhaust smoke at Max (ºC) 190
Mass of smoke (g/s) 9.00

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m³

COMFORT AIR 14

(Max) nominal output power (kW) 14.00
Minimum output power (kW) 4.00
Efficiency at Max (%) 85.00
Hopper capacity (lt) 42.00
Pellet hourly consumption (Min) (kg/h) 0.90
Pellet hourly consumption (Max) (kg/h) 3.30
Efficiency at minimum (h) 30.00
Autonomy (Max) (h) 8.00
Heatable volume (m³) * 344
Smoke outlet (cm) 8
Net weight (kg) 147
Temperature of exhaust smoke at Max (ºC) 260
Mass of smoke (g/s) 9.20

(*) Heatable volume refers to the number of cubic metres that can be heated by the product in an insulated room, therefore with an average calorific requirement of 35 kcal/h per m³

Spread the word

Downloads

Musa M1 – Manual and Installation Guide part 1

Musa M1 – Manual and Installation Guide part 2

Musa UP! M1 – Manual and Installation Guide part 1

Musa UP! M1 – Manual and Installation Guide part 2

Musa air 10 M1 – Technical Sheet

Musa air 10 UP! M1 – Technical Sheet

Musa comfort air 12 UP! M1 – Technical Sheet

Musa comfort air 14 M1 – Technical Sheet

Musa comfort air 14 UP! M1 – Technical Sheet

Spread the word